2 and LabVIEW 8. PCI/PXI-5402/5406 Calibration Procedure. , Israel) for voltage output and a relay box (PXI-5402/2569, National Instruments Corp. NI PXI-5402 New AUTOMATION Controller MODULE DCS PLC Module Company’s Name: Xiamen Xingruijia Import&Export Co. NI PXIe-5840. Synchronized waveform generation (National Instruments, PXI-5402, Cary, NC, USA) and data acquisition (National Instruments, PXIe-6356) boards installed in a PC were used to scan and modulate the. 2) Create your own waveform using primitive LabVIEW functions, and input that to the FGEN. When trying to install & run a PXI-5402 Sig Gen installed in a 1033 chassis, with Max it does not respond and after 10 secs or so gives the errorThis example shows how to initialize the Ag3446x IVI-C driver, read a few properties of the driver, measure AC voltage using Keysight® Technologies 34460A digital multimeter, and output the result in MATLAB®. 1/7 support for the PXI-5404 does not include support for external. An image of the experimental facility and a representative image showing a droplet and measured contact angles is shown in supplemental figure, Fig. 5 V pk-pk into 50 Ω • 0. Engineers choose NI systems to test faster and more efficiently. com or through our contact form. Rent the innovative products you need without up-front costs. NI PXI-5402 New AUTOMATION Controller MODULE DCS PLC Module. As the frequency control word is an integer. REF IN Input Accepts a PLL Reference clock from an external source and can frequency lock the Sample clock timebase to the external Reference clock. PXI-5402 PXI-5154 PXI-5153 PXI-5152 PXI-5142 PXI-5124 PXI-5122 PXI-5114 PXI-5105 PXI-4498 PXI-4496 PXI-4495 PXI. About. First, here is the configuration of my system: PXI Chassis (1045) PXI-8361 controller card (MXI-Express) controlled by a remote computer running the PCI-E controller card. 市場投入までの期間がますます短くなりつつある中、多くのチームは製品の品質を管理することに苦労していますが、クラス最高のテスト組織がその道を切り開いています。 NI PXI-5402/5406 or Agilent 33220A Verifications: • AC amplitude accuracy Sine wave frequency: 50 kHz Sine wave amplitude: • 0. This example shows how to generate a sine wave on a function generator using the National Instruments® NI-FGEN driver in simulation mode. acquisition card (National Instruments, Austin, TX, United States: Model PXI-6281) at 250ksps and post-processed on a personal computer (PC). 20 MHz Bandwidth, 1-Channel, 14-Bit PXI Waveform Generator—The PXI‑5402 is a 20 MHz function generator capable of generating standard functions including sine, square, triangle, and ramp as well as other signals like psuedorandom noise and DC signals. 哪个是PXI硬件合适的设备驱动程序?. The paper is devoted to the theoretical and experimental analysis of an electric circuit consisting of two elements that are described by fractional derivatives of different orders. Hardware Product Lifecycle Policies. This example uses the NIFGEN driver's simulation mode to run without physically connecting any hardware. NI. 1 When the USB Screw Terminal device is powered on, the analog output signal is not defined until after USB configuration is complete. This function generator can generate signals from -5 V to +5 V and uses direct digital. That is not to say, however, that this is impossible. Many teams struggle to manage product quality within shorter and shorter time-to-market windows, but best-in-class test organizations are leading the way. PXI Waveform Generator. The NI 5114 is a 2-channel, 125 MHz oscilloscope. PXIe, 8-Slot (4 Hybrid Slots, 2 PXI Express Slots, 1 PXI Express System Timing Slot), Up to 8 GB/s PXI Chassis —The PXIe‑1082 features a high-bandwidth backplane to meet a wide range of high-performance test and measurement application needs. I have just had LabVIEW 2014 installed on my PC and then I reinstalled NI-FGEN 14. The PXI chassis is NI PXI‐1033. PXIe, 20 MHz Bandwidth, 1- or 2-Channel, 16-Bit PXI Waveform Generator. This documents provides information on calibration service levels available for NI Products. NI InstrumentStudio 2021 Q4 Readme. Figure 2. Community. Lai Wechat:17750010683 Whats app:+86 17750010683Bab 237131 022 Toyota Manual, Pxi-5402 Manual, Manual Estacion Total Sokkia Set 610 K, Sony Drx-830u User Manual, Starry Night Manual Pdf, First Alert Smoke Alarm Manuals, Acronis True Image Workstation 9. What Does a Good Product Data Strategy Look Like?The National Instruments PXI-5402 / PXI-5406 14/16-bit 20/40 MHz Arbitrary Function Generator devices are 100 MS/s, 40 and 20 MHz arbitrary function generators (AFGs) that feature up to 16 bits of resolution and 32 kB of onboard memory for arbitrary function generation in a compact, 1-slot 3U PXI module or PCI board. Power on the computer and install the compatible version of PXI Platform Services. Izdelek z omejitvijo . Figure 12. Some suggested starting points are shown on the left. After 4-us delay time, I need to generate a trigger to another external device. Jūs iepriekš iegādājāties šo produktu. . Configuring the RT Target: After you install all the required software on the host computer, use Measurement & Automation Explorer (NI-MAX) to configure the general. † (PXI) Plug the PXI chassis and the calibrator into the same power. Download the product flyer to learn more about the specifications, benefits, and applications of NI PXI Switch Modules. RoHS. PXI-5406. Back to Product Overview Download Datasheet. NI USRP-2954. To feed that signal back into the switch modules, I figured the best way is to use one of the internal PXI bus channels, to route a trigger signal to the. 0 V to +5. Henry . This document lists specifications for the PXI/PCI-5402/5406 (NI 5402/5406) arbitrary function generator. But now I'm looking for a way to generate a much longer constant pulse: I might need the pulse to go high for up to an hour while I run a test. Solved! Go to Solution. Open a service request. 0 Kudos Message 1 of 5 (3,294 Views) Reply. 我們實驗室買了PXIE-5622、PXIE-5601(RFSA)、PXI-5652(RFSG)、PXI-5402(FGEN)模組以及PXIE-8106控制器、PXIE-106Q機箱,我不知道它們能做什麼,主要是PXIE-5601(RFSA)和PXI-5652(RFSG)我真的不知道它們功用, Return to Home Page; Toggle navigation; Solutions. PXI Express Peripheral Slot 6. pdf. The output voltage of the amplifier was measured by a National Instruments NI-PXI-5122 digitizer. I have a NI PXI 5402 and wish to use its 'sweep' function in TestStand. NI PXI-5402/5406, Keysight 33220A, or Keysight 33500B Verifications: • AC amplitude accuracy Sine wave generation: • Amplitude: – 0. The NI PXI-4071 (Part Number: 778271-01) is a FlexDMM, multifunction 3U PXI module that gives the estimation ability found in a high-resolution digital multimeter (DMM) and a digitizer. This example shows how to initialize the Ag3446x IVI-C driver, read a few properties of the driver, measure AC voltage using Keysight® Technologies 34460A digital multimeter, and output the result in MATLAB®. top of the PXI chassis. 25 MS/s (1-Channel), 32 Analog Inputs; NI PXI-4071 PXI Digital Multimeter (DMM) NI PXI-5402 20 MHz Arbitrary Function Generator; NI PXI-4110 Triple-Output Programmable DC Power Supply (x2) Measuring Parameters. Keysight N1021B Differential TDR / TDT Probe 18 GHz. NI InstrumentStudio 2022 Q3 Readme. sbRIO-9632 National Instruments, NI, sbRIO-9632 National Instruments sbRIO-9632 National Instruments Module Clips Drive controller servo motor Contact: Mr. 7. NI PXI-6259 16-Bit, 1 MS/s (Multichannel), 1. PXIe, 9-Slot (8 Hybrid Slots), Up to 8 GB/s PXI Chassis. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. 1 in. , Ltd. Use the Ag3446x driver to measure AC voltage from a digital multimeter and output the result. You can also use InstrumentStudio to monitor and control devices being used in external. com Note Unless manually disabled, NI-FGEN automati cally loads with the operating system and enables the device. vi 49 KB. PXI-5402 20MHz 3 Years 779657-01 3958561 Data Sheet. When you make a frequency list, you need to choose a sequence of waveforms and the length of each sequence. They were actuated using a 1 kHz AC signal that was produced by an NI PXI-5402 signal generator and amplified to 200 V rms using a Trek PZD700A amplifier. The circuitry has several resistors and a step down transformer in the path. † (PXI) Plug the PXI chassis and the calibrator into the same power. This arbitrary waveform generator can generate signals from -6 V to +6 V and uses direct digital synthesis (DDS) to precisely generate waveforms. Solution. PXI-5402. PXI-5402 functional generator. Solution. Manufacturer: National Instruments. Technology evolution, market demand, and component obsolescence dictate the lifecycle of a given NI hardware product. The frequency control word is calculated by dividing the desired output frequency by the sample clock frequency (100MHz for a PXI-5402) and multiplying it by 2^N where 'N' is the width of the DDS accumulator (48 for the PXI-5402). Scope: PXI-5114. When you use the PLL (items 1 and 2 above), the frequency. The clock frequency needs to change when triggered by events on the FPGA. Equipment: NI PXI-8106 PC, NI-PXI 5671 RF vector signal generator and NI-PXI 5661 RF vector signal analyzer, NI PXI digital and analog I/O cards, GPIB controlled multimeter, Linksys router. SINE out voltage amplitude of 2 Vpk-pk with a 50 Ω load. For additional information visit Instrument Control. 硬件: Signal Sources (AWG/FG/AO)>>Arbitrary Waveform and Function Generators>>PCI-5402, Signal Sources (AWG/FG/AO)>>Arbitrary Waveform and Function Generators>>PXI-5402 Ambient temperature range of 0 °C to 50 °C. Waveform Generator, PXI-5402, 1. 1 Vpk-pk to 5. Waveform summing. PXIe, 500 MHz or 1. com Note Unless manually disabled, NI-FGEN automati cally loads with the operating system and enables the device. Unless otherwise noted, the following conditions were used for each specification: • Analog filter enabled. Outputs of multiple PXI-5402 signal generators can be connected together. Ezt a terméket Ön korábban megvásárolta. NI PXI-5402/5406 or Agilent 33220A Verifications: • AC amplitude accuracy Sine wave frequency: 50 kHz Sine wave amplitude: • 0. 20 mhz带宽,单通道,14位pxi波形发生器—pxi-5402是一款20 mhz函数发生器,能够生成正弦波、方波、三角波和斜波等标准函数以及伪随机噪声和直流信号等其他信号。函数发生器可以生成-5 v~+ 5 v的信号,并使用直接数字合成(dds)技术精确生成波形。From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. accuracy of the NI 5402/5406 is solely dependent on the. I can open the NI FGEN Soft Panel on its own and can use the sweep function manually. You can use MATLAB together with Instrument Control Toolbox as your single software environment to configure, control, and create waveforms with these instruments. The parameters space of the optimization problem concern the voltage amplitude, the burst frequency and the duty-cycle (Figure 3). 8 in. pXI-5402 function generator (national Instruments, austin, TX) being controlled by a computer in pXI chas-sis. c. Touch any metal part of the chassis to discharge static electricity. Drives / Motion / Motor Control / Positioning. MHz, 2V sinusoidal AC signals from eight NI-PXI-5402 signal generators (National Instruments) to the eight Figure 1: (A) Cell rotation around an axis parallel to the optical axis. 100 MHz, 32-Channel, 5 V PXI Digital Waveform Instrument. This IVI driver is for use with NI function generators and arbitrary waveform generators. This file contains important information about InstrumentStudio 2019 SP1, including supported hardware and operating systems, a partial list of bugs fixed, and known issues. NI PXI/PCI-5402/5406 Specifications 14/16-Bit, 20/40 MHz Arbitrary Function Generator This document lists specifications for the NI PXI/PCI-5402/5406 (NI 5402/5406) arbitrary function generator. 1230 вузов, 4395 предметов. Войти / Регистрация. NI PXI-540X ACCESS ACTIVE CH 0 CH 0 REF IN SYNC OUT/ SYNC PFI 0 OUT/ PFI 0 PFI 1 PFl 1 NI PCI-540X Figure 1. The PXIe-8398 enables control of a PXI Express chassis from an external host, such as a desktop PC, rackmount controller, or a separate master chassis. Both the NI PXI-5402 and NI PXI 4472B are housed in a NI PXI-1033 chassis, controlled via the same LabVIEW interface mentioned before. With MATLAB, you can analyze and visualize data for signal processing, statistical analysis,. Since simulation mode is enabled, the resource name can be specified as empty. used. Using these devices, you can combine(PXI actually stands for PCI Extension for Instrumentation!) However, you do want to ensure that your PXI Platform Servcies and VISA drivers are compatible. I'm really surprised because it's a big limitation. Reboot the PXI controller and try a different PXI slot that's known to be working and/or different chassis If none of these work, then an RMA would probably need to be set up for the device, and you can achieve this by contacting NI technical support. NI PXI-5402 New AUTOMATION Controller MODULE DCS PLC Module. ##Technical Specifications -Frequency range:DC to 20 MHz -Output amplitude range:2 mV to 20 Vpp into 50 ohms -Amplitude resolution:1 mV -Offset range:±10 V -Offset resolution:1 mV -Phase resolution:0. PXI-5402 National Instruments Arbitrary Waveform Generator. AU Automation Mall 1PC USED NI PXI - 5402 Waveform Signal Function Generator 14-bit Notice: Because,the international air shipping forbid to ship liquid,powder and batteries, If you purchased goods containing such. PXI RF Relay Module. Return to Home Page; Toggle navigation; Solutions. 20 MHz Bandwidth, 1-Channel, 14-Bit PXI Waveform Generator—The PXI‑5402 is a 20 MHz function generator capable of generating standard functions including sine, square, triangle, and ramp as well as other signals like psuedorandom noise and DC signals. So far to keep it simple I am just testing the triggering part using the PXI_trig0 line, and trying to tell. • Ensure that the PXI chassis fan speed is set to HIGH, that the fan filters (if present) are clean, and that the empty slots contain slot blockers and filler panels. Simulating a device that is not supported on your operating system results in indeterminate behavior. 5 GS/s or 5 GS/s, 10-Bit PXI Oscilloscopes Note Before you begin, install and configure your chassis and controller. This document lists specifications for the NI PXI/PCI-5402/5406 (NI 5402/5406) arbitrary function generator. But now I'm trying to take an example for Visual Studio provided with FGEN and modify it to operate the PXI-5402 program. the NI PCI/PXI-5402/5406 arbitrary function generators. Stepped Trigger Mode. The hybrid connector type in every peripheral slot enables the most flexibility in terms of instrumentation module placement. The NI 5114 ships with the NI-SCOPE instrument driver, which you use to program the device. Perspectives. e. See all Driver Software Downloads. 20 MHz Bandwidth, 14-Bit Waveform Generator Device —The PCI‑5402 can generate standard functions, including sine, square, triangle, and ramp as well as other signals like pseudorandom noise and DC signals. NI Product Documentation Center. 9 supports pxi-5401 on WinXP only. Use the AgAC6800 driver to make measurements from an AC power supply and output the result. 5 GS/s . Lab. Part Number(s): 784782-01 |Destinations (PXI trigger lines 0 to 7)18 Polarity Active high (not configurable) Pulse width 230 ns Calibration Interval Recommended calibration interval 1 year Physical Dimensions 3U, one-slot, PXI Express/CompactPCI Express module 2. NI 5402/5406 Calibration Procedure 6 ni. ) Weight 394 g (13. 15 days free replacement for quality problemsHello all, Hopefully this is just an easy to answer question, but since I got so stuck on this I'll ask it anyway. 1) Use a Frequency List. In Emulation mode, when you change the frequency on-the-fly / dynamically while generating, the waveform will not be phase continuous. This page documents all the applicable standards and certifications for the PXI-5402 and provides downloadable certifications. 理想的测试系统可以认为是其组成部分的总和,包括测量和激励硬件,信号切换,电缆以及可能 的大规模互连系统,UUT电源,外部PC或嵌入式控制器,操作系统 (OS)和编程环境。. 每个部件根据诸如UUT测试参数. If your PC is unable to see your modules associated with your PXI chassis, try shutting down and then repowering your PC while your NI Chassis is connected and powered on with its associated modules connected. I went to the Measurement Studio tab in Visual Studio, and then to. The PXIe-1088 features an all-hybrid backplane to meet a wide range of high-performance test and measurement application needs. SD Pre. Windows Embedded Standard 7 (SP1). vi (see attached) using an NI PXIe-1073 + NI PXI-5402 + NI PXI-5122 and LabVIEW 2013. M. NI™ manufactures arbitrary waveform and function generators that use the NI-FGEN driver. ECK MC. Description:NI PXI-5402 central processing unit About Us We mainly manage PLC module, DCS module, CPU module, IO module, DO module, AI module, DI module, network communication module. RoHS. More information about the Frequency List Mode can be found here. Use the AgAC6800 driver to make measurements from an AC power supply and output the result. 我想在任意波形输出模式下使用ni 5402,但是出现了-1074135039 “无效输出模式” 的错误,请问这是为什么? (错误如图1所示. Windows Server 2012 R2 64-bit. PXIe, 500 MHz or 1. You can request. 20 MHz Bandwidth, 1-Channel, 14-Bit PXI Waveform Generator—The PXI‑5402 is a 20 MHz function generator capable of generating standard functions including sine, square, triangle, and ramp as well as other signals like psuedorandom noise and DC signals. NI PXI-5402 New AUTOMATION Controller MODULE DCS PLC Module. 00. This is a hybrid-slot compatible PXI module that can be used in both PXI Express hybrid slots and standard PXI slots. 0 Vpk-pk into 50 Ω – 0. NI 5406 and NI 5402 devices are 100 MS/s, 40 and 20 MHz arbitrary function generators (AFGs) that feature up to 16 bits of resolution and 32 kB of onboard memory for arbitrary function generation in a compact, 1-slot 3U PXI module or PCI board. Use the AgAC6800 driver to make measurements from an AC power supply and output the result. National Instruments PXI-5402 14-Bit 20 MHz Arbitrary Function Generator This is a hybrid-slot compatible PXI module that can be used in both PXI Express hybrid slots and standard PXI slots. Generally speaking the PWR OK, PWR/LINK or PWROK/FAULT LED should remain lit, and the Drive LED should blink during boot as the disk is accessed. 市場投入までの期間がますます短くなりつつある中、多くのチームは製品の品質を管理することに苦労していますが、クラス最高のテスト組織がその道を切り開いています。NI PXI-5402/5406 or Agilent 33220A Verifications: • AC amplitude accuracy Sine wave frequency: 50 kHz Sine wave amplitude: • 0. PXI-5402 PXI-5154 PXI-5153 PXI-5152 PXI-5142 PXI-5124 PXI-5122 PXI-5114 PXI-5105 PXI-4498 PXI-4496 PXI-4495 PXI-4462 PXI-4461. Try searching for what you need. October 2022. First, here is the configuration of my system: PXI Chassis (1045) PXI-8361. CLOCK out level of 5 V. The instruments are from left to right function generator NI PXI‐5402, dualchannel oscilloscope NI PXI‐5112, DC power supplyNI PXI‐4110 with APS‐4100, and DMM NI PXI‐4070. MODULE ASSEMBLY, NI PXI-5402 ROHS. skype:628652ed16045b6e The National Instruments PXI-5402 / PXI-5406 14/16-bit 20/40 MHz Arbitrary Function Generator devices are 100 MS/s, 40 and 20 MHz arbitrary function generators (AFGs) that feature up to 16 bits of resolution and 32 kB of onboard memory for arbitrary function generation in a compact, 1-slot 3U PXI module or PCI board. Using these. PXI-5402 Fgen running niFGEN 2. I am able to use the Test Panels in MAX to verify the generator is working. Different orders of differentiation lead to. This document explains how to install, configure, and test the PXIe-5160/5162. The components to be used in test circuits are installed in the matrix in sockets near the edge of some of the boards. RoHS. S. 5 Digit Multimeter Passive Testing Specifications. The PZD700A is a high-voltage DC-stable piezo driver/amplifier. I'm working on a project where I need to route a data marker event from a PXI 5402 function generator to a PXI 2521 via te PXI trigger bus on the backplane. NI PXI/PCI-5402/5406 The NI 5402 is a 20 MHz bandwidth,14-bit arbitrary function generator. The best replacement for this device will be a PXI, PXIe, or CompactDAQ chassis that is capable of housing all required PXI or C Series I/O modules. NI PXI Platform Services is already included as part of NI instrument drivers, but there may be cases where only the PXI Platform Services software is needed for certain applications, such as using NI MXI products or using NI PXI or PXI Express chassis without installing other NI PXI hardware drivers. NI uses several internal processes to track these factors and manage the lifecycle of NI hardware products. Waveform Generator Device, PCI-5402, 1 Channel, 20 MHz Sine/Square, 1 MHz Triangle/Ramp. Fungen: PXI-5402 (x2) Hello . $4,900. FGen sweep function TestStand. Table 1 summarizes the magnet pack-age parameters. しかし、1つの波形だけであれば、ユーザー定義の波形を出力することができます。. darab 1+ 1 250 371,10 Ft. This document explains how to install, configure, and test the PXIe-5160/5162. Rent the innovative products you need without up-front costs. E-Mail:2322181769@qq. Since simulation mode is enabled, the resource name can be specified as empty. I believe you can achieve single cycle generation using list frequency mode. InstrumentStudio allows you to generate and acquire measurements from multiple devices within a single application. 0 but I believe it said there was either a patch/service pack or newer version available. When the user clocks the module’s digital lines at 10 MHz, then they can utilize the lines for pulse-width modulation to control pumps, valves, lamps, fans, and motors. With MATLAB, you can analyze and visualize data for signal processing, statistical analysis. You can use MATLAB together with Instrument Control Toolbox as your single software environment to configure, control, and create waveforms with these instruments. PXI Controller. This arbitrary waveform generator can generate signals from -6 V to +6 V and uses direct digital synthesis (DDS) to precisely generate waveforms. 20 MHz Bandwidth, Single Channel, 14-bit PXI Waveform Generator – The PXI-5402 is a 20 MHz function generator capable of generating standard functions such as sine, square, triangle and ramp standard functions such as sine,. 5 Hz AC/DC-Coupled, 8-Input PXI Sound and Vibration Module. 0, National Instruments, Austin, TX) to plan the droplet transport routes and to output the signal to switch relays to turn on or off through a relay mod-PXI-5402. NI TestStand Software. NI PXI Platform Services is already included as part of NI instrument drivers, but there may be cases where only the PXI Platform Services software is needed for certain applications, such as using NI MXI products or using NI PXI or PXI Express chassis without installing other NI PXI hardware drivers. This file contains installation instructions and compatibility information for Instrument Studio 2022 Q1. Email: PXI-1031 National Instruments PXI-1031 PXI Chassis with Universal AC from National Instruments | Buy Today from Artisan. . I've got a PXI-5402 that I'm using in an application to generate single pulses of a square wave (durations of 5-100mS or so). These devices have four BNC connectors, as shown in the following figure. Unfortunately I discovered that the DC offset for this last is only 50% of amplitude despite a more wide range of the PXI-5402: I'm really surprised because it's a big limitation. That is not to say, however, that this is impossible. The NI 5406 is a 40 MHz bandwidth, 16-bit arbitrary function generator. vi (see attached) using an NI PXIe-1073 + NI PXI-5402 + NI PXI-5122 and LabVIEW 2013. I ran NI MAX, removed the 5402 from the config. † Interpolation set to maximum allowed factor for a given sample rate. . All Manuals. This signal is applied to an attenuator. 理想的测试系统可以认为是其组成部分的总和,包括测量和激励硬件,信号切换,电缆以及可能 的大规模互连系统,UUT电源,外部PC或嵌入式控制器,操作系统 (OS)和编程环境。. It looks like NI FGEN 2. NI PXI-5402/5406 or Agilent 33220A Verifications: • AC amplitude accuracy Sine wave generation: • Amplitude: – 0. Refer to theUse the Ag3446x driver to measure AC voltage from a digital multimeter and output the result. The capabilities listed in this document represent capabilities available at National Instrument and Certified Calibration Center labs. +. InstrumentStudio 2018 allows you to generate and acquire measurements from multiple devices within a single application. NI 5402/5406 Calibration Procedure 6 ni. 5 GS/s . I am attempting to synchronise these modules to continuously generate patterns and read data. 1) NI- PXIe-6535 HSDIO and 2) NI PXI-5402 function generator. • A PXI Express embedded controller or PC with MXI controller system that meets the system requirements specified in this guide and chassis documentation. We calibrated (self calibration) PXI 5402 using NI max. The digital lines on the PXI-6250 module can drive 24 mA for actuator and relay control. This function generator can generate signals from -5 V to +5 V and uses direct digital synthesis (DDS). Use the NIFGEN driver to generate a sine wave on a function generator. Part Number: 192887B-01, 192887C-01,. Figure 10. Perspectives showcases how NI sees what’s next in the world of test and technology. Use the AgAC6800 driver to make measurements from an AC power supply and output the result. Waveform Generator, PXI-5402, 1 Channel, 40 MHz. Hi there, I belive that what you are trying to achieve would be best achieved using the arbitrary function mode, unfortunately this isn't supported by the PXI-5402. The CH 0 output can be connected to a 50 Ω, ±12 V source without sustaining any damage. NI PXI-5402 or Agilent 33220A Verifications: • AC amplitude accuracy Sine Wave Frequency: 50 kHz. I have just had LabVIEW 2014 installed on my PC and then I reinstalled NI-FGEN 14. 0 the latest FGEN driver? NI PXI-5402/5406—PXI_CLK10 (backplane connector) NI PCI-5402/5406—RTSI_7 (RTSI_CLK) 3. forum qustion project 2. com. Example: Hardware Input and Outpur => Modular Instruments => NI-FGEN => Standard Function Generation => Fgen Sweep Generator. Systems Engineering Software. TEL/WeChat:15396237607. Please select your country. You can use MATLAB together with Instrument Control Toolbox as your single software environment to configure, control, and create waveforms with these instruments. NI PXI-5402/5406. Waveform Generator, PXI-5402, 1 Channel, 20 MHz. PXI-5402 has Direct digital synthesis (DDS) capability which is used to precisely generate waveforms that are repetitive in nature, including sine, square, triangle. You can use MATLAB together with Instrument Control Toolbox as your single software environment to configure, control, and create waveforms with these instruments. PXIe, 43 MHz Bandwidth, 1-Channel, 16-Bit Onboard Signal Processing, PXI Waveform Generator. I am looking for a pxi card to generate 3 channels analog outputs. NI PXI-5402 14-bit, 100 MS/s Function Generator, 20 MHz Sine/Square; NI PXI-4110 Triple Output DC Power Supply with APS-4100 Aux Power; NI PXIe-5122, 2-ch, 100 MS/s Digitizer w/256 MB/ch Onboard Memory; Luna Hyperscan - High resolution and sensitivity multiple fiber optic strain provides diagnostic capability of structures and materials. 解決策: NI 5402/5406は、任意波形発生器ではなく、任意関数発生器となりますので、任意の波形を自由に出力することはできません。. Check any fuses or circuit breakers in the chassis or other power. With MATLAB, you can analyze and visualize data for signal processing, statistical analysis,. pdf. 20 MHz Bandwidth, 1-Channel, 14-Bit PXI Waveform Generator—The PXI‑5402 is a 20 MHz function generator capable of generating standard functions including sine, square, triangle, and ramp as well as other signals like psuedorandom noise and DC signals. Updated 2023-02-21. Caterpillar G3516 Generator Set. This arbitrary waveform generator can generate signals from -12 V to +12 V and uses a fractional. Environment NI PXI-5402/5406 Environment. May be pxi 6711 can be sufficient. I've got a PXI-5402 FGen and several PXI-2521 switch blocks in a PXI-1033 chassis. 1. i have noticed that the low limits and high lim. These elements are designed and performed as RC ladders with properly selected values of resistances and capacitances. Note: Ensure your PXI(e) target, LabVIEW, Real Time module and Device Drivers are compatible with selected software version. Use the AgAC6800 driver to make measurements from an AC power supply and output the result. 20 MHz Bandwidth, 1-Channel, 14-Bit PXI Waveform Generator —The PXI‑5402 is a 20 MHz function generator capable of generating standard functions including sine, square, triangle, and ramp as well as other signals like psuedorandom noise and DC signals. hwdb | 249 +++++ hwdb/20-pci-vendor-model. This example shows how to generate a sine wave on a function generator using the National Instruments® NI-FGEN driver in simulation mode. Hi - I am trying the Stimulus_Response_Example. This example shows how to generate a sine wave on a function generator using the National Instruments® NI-FGEN driver in simulation mode. Specifications. We are evaluating using the pxi-4072 along with the pxi-2530 multiplexor to measure ~ 82pf tuning caps on die during wafer probe. NI. This example shows how to generate a sine wave on a function generator using the National Instruments® NI-FGEN driver in simulation mode. To see this PDF, click the link to view the requested file: 371707e. No damage occurs if the CH 0 output is. Provides support for NI GPIB controllers and NI embedded controllers with GPIB ports. procedure is intended for. The PCI-5402 features the direct digital synthesis (DSS) method for signal generation. † (PXI) Ensure that the PXI chassis fan speed is set to HI, that the filter fans are clean, and that the empty slots contain filler panels. Many teams struggle to manage product quality within shorter and shorter time-to-market windows, but best-in-class test organizations are leading the way. If the PLL. Power on the computer and reset the MAX database. Also, you might want to try a repair install of PXI Platform Services. I would appreciate any ideas / suggestions. The circuitry has several resistors and a step down transformer in the path. With MATLAB, you can analyze and visualize data for signal processing, statistical analysis,. This function generator can generate signals from -5 V to +5 V and uses direct digital. PXI-5402 20MHz 3 Years 779657-01 3958561 Data Sheet. This document lists specifications for the NI PXI/PCI-5402/5406 (NI 5402/5406) arbitrary function generator. Contact: Jenny. Control NI-FGEN devices and create your own arbitrary waveforms using MATLAB. As it is a A PXI-5412 would be better suited to this task. The versatile supply rails and high accuracy make the PXI-4110 single-quadrant power supply for design validation and manufacturing test applications. Output Attenuation. The NI 5406 is a 40 MHz bandwidth, 16-bit arbitrary function generator. Details. You can use MATLAB together with Instrument Control Toolbox as your single software environment to configure, control, and create waveforms with these instruments. $200. View all articles. Each power supply is capable of supplying entire system power, allowing power supply replacement without interrupting system operation. PXI. Войти РегистрацияNeed to retrieve a quote for your NI products? Use this simple tool to access your online quotes and lock in prices for 30 days. Try searching for what you need. Use the AgAC6800 driver to make measurements from an AC power supply and output the result. Connecting to PXI-5402 instrumentation is easy with SCOUT. PXI-5402 PXIe-6363 PXI-6289 PCI-781XR PXI-5105 PCI-1428 PCIe-6259 NI-9012 USB-6251 PXI-2520 PXIE-6674T PCI-4454 PXI-4472 PXI-5142 PXIe-8133 SWB. InstrumentStudio allows you to generate and acquire measurements from multiple devices within a single application. While this is a task that is better suited for our Arbitrary Waveform Generators, perhaps you could use the Fgen Sweep Generator. They offer various configurations and features, such as high current, high voltage, and high density. com. † (PXI) Ensure that the PXI chassis fan speed is set to HI, that the filter fans are clean, and that the empty slots contain filler panels. NI PCI/PXI-5402 20MHZ ARBITRARY FUNCTION GENERATOR EDITION DATE May 2014 Contact: 866-275-6964 NI PART NUMBER 374617A-01 [email protected] teams struggle to manage product quality within shorter and shorter time-to-market windows, but best-in-class test organizations are leading the way. 6 cm (0. after a successful run of the procedure for the PXI-5402 Signal Generator with no failures, the report generates failures on the "as left" column of the test results. Power on the computer and install the compatible version of PXI Platform Services. The PXIe-5160 is a 500 MHz , 10-bit oscilloscope with a sample rate of up to 2. † (PXI) Plug the PXI chassis and the calibrator into the same power. This calibration. The function generator provides the square-wave modulation signal (duty cycle. The NI PXI-5402 (Part Number: 779655-01, 192887E-01L) is a 20 MHz Waveform Generator fit for producing standard functions including sine, square, triangle, ramp, and different signals like psuedorandom noise and DC signals. Spec PXIe-5413 DC offset PXIe-5413 . • Ensure that the PXI chassis fan speed is set to HIGH, that the fan filters (if present) are clean, and that the empty slots. It is also shielded. Part Number: 192887B-01, 192887C-01, 779655-01. * Nota: La diferencia es con un generador de funciones (es decir PXI-5402) y un generador de forma de onda (es decir un PXI-5422) es lo que la forma de onda necesita para estar con un tamaño estándar porque es una función, no una forma de. 20 MHz Bandwidth, 14-Bit Waveform Generator Device —The PCI‑5402 can generate standard functions, including sine, square, triangle, and ramp as well as other signals like.